FOX18-XM
5V / 3000mA worldwideQuantity | Unit price |
---|---|
To 24 | €25.02 * |
From 25 | €22.48 * |
From 50 | €21.59 * |
From 250 | €19.65 * |
From 500 | €16.91 * |
- Order number: 1898133
- Availability:
-
Delivery time:
Germany 4-5 working days, Europe 6-7 working days, worldwide 14 working days
Maximum order quantity: 750 pcs
High efficiency: up to 86.9% Low no load power consumption Meets DoE efficiency level VI CoC... more
Required Accessories
For the operation of this device you need a primary adapter and a secondary adapter . This can be found here:
Primary adapters and Secondary adapters
Primary adapters and Secondary adapters
Product information "FOX18-XM"
High efficiency: up to 86.9%
Low no load power consumption <90mW
Meets DoE efficiency level VI
CoC version 5 ready
Ultra-low leakage current ≤10μA
IEC 60601-1-2, 4th edition
Ultra-wide operating temperature range 0 - 50°C
Isolation 2x MOPP
Double housing safety: snapped & welded
IP42 approved interchangeable plug system as additional accessories
IEC 60601-1-11 ready with IPX2 adapter
New release with 5000m operating altitude
Low no load power consumption <90mW
Meets DoE efficiency level VI
CoC version 5 ready
Ultra-low leakage current ≤10μA
IEC 60601-1-2, 4th edition
Ultra-wide operating temperature range 0 - 50°C
Isolation 2x MOPP
Double housing safety: snapped & welded
IP42 approved interchangeable plug system as additional accessories
IEC 60601-1-11 ready with IPX2 adapter
New release with 5000m operating altitude
Additional information
- Family : FOX18 medical
- Current: 3000 mA
- Means of Protection: Input Output 2xMOPP, Input - Ground 1xMOPP
- Gehäuse / Housing: FOX18 medical
- Output voltage: 5 V
- Frequency: 50 / 60
- AC Input: FRIWO interchangeable mains plug system: see Primary Adapters
- Humidity: 10% bis 90%
- Working temperature: 0°C - 50°C
- Storage temperature
: -40°C - 70°C - MTBF: 200.000h acc. Mil217F (based on calculations at
120Vac/60Hz & 230Vac/50Hz, ambient 25°C
and 100% load) (The MTBF are theoretically determined values, which does not guarantee the lifetime of the product or of the electrolytic ) - Standard: IEC/EN/UL60601-1 3.1 Edition
- DC output: Universal output plug system
- Input tolerance: ±10%
- Input voltage: 100-240 V
- Protection Class: II
- Spec.0 cover sheet FW-Type: FW8001M/05
- color: black
- Inrush current: <50
- Storage Humidity: 10-90%
- Atmospheric pressure: 70-106 kPa
- Line Regulation: ±1
- Load Regulation: ±4
- Hold up Zeit: >20ms(120V), >50ms(230V)
- material: PC-ABS
- Approbations: Europe, USA, Australia, Japan
- Housing Flame Class: UL 94 V0
- IP Rotection rating: IP40
- Overload protection: JA
- Short Ciruit protection: JA
- Over Voltage Protection: JA
- Condcted and Radiated Emmisions: EN55022, EN55011, FCC15, Class B, EN60601-1-2, IEC60601-1-2 4th Edition
- Immunity
: EN55024, EN60601-1-2, IEC60601-1-2 4th Edition - Harmonics: EN61000-3-2
- Flicker noise: EN61000-3-3
- ESD (contact/ air): EN61000-4-2
- Immunity against radiated field: EN61000-4-3
- ETF/ Burst: EN61000-4-4
- Surge: EN61000-4-5
- Immunity against conducted disturbances: EN61000-4-6
- Voltage dips: EN61000-4-11
- Immunity against magnetic field: EN61000-4-8
- Drop test: Standard: IEC60068-2-32, Surface: steel, Drop height: 1m, Numbers of Drops (total): 3
- Vibration: Standard: IEC 60068-2-6, Frequency range : 10 – 500 Hz, Cross- over-frequency : 58 – 62 Hz, Displacement amplitude : 0.2mm, Peak acceleration : 3 g, Number of cycles: 10 per axis